Bulletin PC-CPS-1
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: [email protected]
Specifications - Installation and Operating Instructions
Series CPS Cable Pull Switch
The Series CPS Cable Pull Switch is designed to provide a
switching system to isolate the power to the conveyor system or
other similar process equipment in event of a shut-down condi-
tion. A steel wire is placed along the side of the conveyor and at-
tached to the cable pull switch. When the cable is pulled at any
point along the conveyor it will trip the cable pull switch causing
the conveyor to shut down. To restart the conveyor the CPS
must be manually reset. The series CPS has a universal design
for bi-directional activation and utilizes a highly visible red flag to
indicate the switch status. The compact design makes it ideal for
easy installation.
APPLICATIONS
Conventional Belt Conveyors
Ship Loading/Unloading Systems
Stacker/Reclaim Conveyors
Apron Feeder Conveyors
Tripper or Shuttle Conveyors
Bucket Elevators
Horizontal Feed Systems
SPECIFICATIONS
Temperature Limits: -4 to 140°F (-20 to 60°C).
Enclosure: Die cast aluminum.
Enclosure Rating: NEMA 6 (IP 67).
Switch Type: 2 SPDT.
Electrical Rating: 10 amp @ 125/250 VAC; 1/2 amp @ 125
VDC.
Electrical Connection: 3 screw type, common, normally open,
normally closed.
Electrical Conduit: Two 3/4˝ female NPT.
Activation Angles: 30 degrees.
Activation Force: 11 +/- 2.25 pounds.
Control Type: Manual reset.
Weight: 6.4 pounds.
OPERATION-INDICATING
PLATE
INSIDE VIEW
CAMS
INSULATORS
MICROSWITCHES
5-1/8
[130.18]
3-7/16
[87.31]
2-9/16
[65.09]
1-1/8
[28.58]
19/32
[15.03]
COVER BOLTS
4X M10
RESETTING
LEVER
63/64
[25]
CASE
COVER
61/64
[24.21]
3-23/64
[85.33]
1-31/32
[50]
29/32
[23.02]
1-31/32
[50]
51/64
[20.24]
6-1/16
[153.99]
1/8
[3.18]
LEVER
2-21/64
[59.13]
3-15/16
[100.01]
2X 3/4˝
NPT
SHAFT
3-15/16
[100.01]
8-7/16
[214.31]
2-15/64
[5.95]
PULLING DIRECTION
1/4
[6.35]
30°
LOCK POSITION
31/64
[12.3]
2-49/64
[70.25]
2X 2-11/64
[55.17]
2-9/16
[65.09]
2X 1-1/2
[38.1]
5-1/8
[130.18]
1-37/64
[40.08]
9/32
[7.14]
ø13/32 [10.32]
MOUNTING HOLES
SHACKLES
OPERATING DIRECTION
PC-CPS-1:TEMPLATE 7/10/09 10:11 AM Page 1
Zobrazit stránku 0
1 2 3 4

Shrnutí obsahu

Strany 1 - DWYER INSTRUMENTS, INC

Bulletin PC-CPS-1DWYER INSTRUMENTS, INC.Phone: 219/879-8000 www.dwyer-inst.comP.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-

Strany 2

Operation PrincipleThe CPS is designed to provide a switching system to isolate thepower to conveyor system and other equivalent processequipment i

Strany 3

WIRE CUPCABLEMOUNTING BASEFRAME OF BELT CONVEYOR6˝8.25˝4.5˝InstallationEye bolts should be prepared before installation, and should bespaced according

Strany 4

WiringThe Cable Pull Switch has 2 SPDT relays that can be accessedby removing the cover. The independent relays can be used tocontrol two separate cir